Line 39: Line 39:
  
 Platform Access – Disable encryption code when applicable.  Platform Access – Disable encryption code when applicable. 
 +
 +------------------------------------------------------------
 +**Video Settings**
 +
 +
 +Video/Audio 
 +
 +Video – You will need to check both the Main and Sub- streams.  
 +
 +Video Type – Ensure each Channel No. is set to the proper type. If IP cameras, select “Video & Audio.” 
 +
 +Resolution – Should be the highest option possible.  
 +
 +Bitrate – Variable 
 +
 +Video Quality - Higher 
 +
 +Frame Rate – Should be set at 20 for Main and Full Frame Rate for Sub  
 +
 +Video Encoding – H.265 when applicable. 
 +
 +H.264+/H.265+ - OFF 
 +
 +Channel-zero – Disabled 
 +--------------------
 +**Other Settings like Image, OSD(On Screen Display)**
 +
 +Image 
 +
 +OSD Settings – This is where you will label each camera. 
 +
 +Event  
 +
 +Video Loss – Click Enable Video Loss Detection and Send Email under the Linkage Method on each channel.  
 +
 +Exception – Enable Send Email for all Exception Types (EXCEPT HDD Full and Illegal Login). Disable all Audible Warnings.  
 +
 +Storage  
 +
 +Schedule Settings – Ensure each channel has recording enabled. If audio, you will have to click Advanced to ensure Record Audio is enabled as well.  
 +
 +Storage Management – This is where you will format the hard drive and check the status of it.  